www.tarekdata.com

Steel structure Warehouse G+M Revit 3D BIM model


Seismic Force Calculation as per ASCE-7-10 (American standard)

Non Structural Components

On this page you can find the Seismic Force Calculation formulas as per ASCE-7-10 for Non Structural Components, considering the different factors as per code with a unit dead load.

Note 

   The Seismic force shall be calculated according to the equation (13.3-1) from the code then it will be compared to the maximum and minimum value from equations (13.3-2) & (13.3-3) respectively.
Therefore,
if the calculated value of seismic force is bigger than the min. and less than the max. value, then it will be adopted for the design.
if the calculated value is less than the min. then the minimum value shall be used in the design.
if the calculated value is bigger than the max. then the maximum value shall be used in the design.

 

ap

 

1

amplification factor

 

Ss

 

0.09

0.2s spectral acceleration

 

Fa

 

2.5

site coefficient

 

SMS

Fa*Ss

0.225

 
 

SDS

2/3*SMS

0.15

Spectral acceleration

 

z/h

 

1

elevation ratio

weight  

Wp

 

1

unit dead load

 

Rp

 

2.5

architectural coefficient

 

Ip

 

1

importance factor

calculated  

Fp1

0.4*ap*SDS*Wp/(Rp/Ip)*(1+2*z/h)

0.072

(13.3-1)

max.  

Fp2

1.6*SDS*Ip*Wp

0.240

(13.3-2)

min.  

Fp3

0.3*SDS*Ip*Wp

0.045

(13.3-3)

 

To be used for the design

TurboSquid.com Home Page