www.tarekdata.com

Steel structure Warehouse G+M Revit 3D BIM model


Loads combinations according to Eurocode 1

The loads combinations are combinations of load cases for which the structure is designed and checked.

On this page you can find the loads combinations at serviceability limits states SLS and ultimate limits states ULS ready for using including the accidental limits states ALS, generated according to Eurocode-1 considering the dead loads and varying loads (live, wind and thermal) and accidental (seismic).

Loads cases considered :

  • G : dead load

  • Q : live load

  • W : wind load

  • Temp : thermal effect

  • SEI : seismic load


The content of this page is available also in other language:

  

Case where we have : G & Q & W


SLS   Eurocode-1

1) G + Q + 0.6 W
2) G + Q
3) G + 0.7 Q + W
4) G + W

ULS   Eurocode-1

1) 1.35 G + 1.5 Q + 0.9 W
2) 1.35 G + 1.5 Q
3) G + 1.5 Q + 0.9 W
4) G + 1.5 Q
5) 1.35 G + 1.05 Q + 1.5 W
6) 1.35 G + 1.5 W
7) G + 1.05 Q + 1.5 W
8) G + 1.5 W

Note 

   regarding the wind case, you have always to think to consider positive and negative case, means pressure/suction loading

Case where we have : G & Q & W & Temp


SLS   Eurocode-1

1) G + Q + 0.6 W + 0.6 Temp
2) G + Q + 0.6 W
3) G + Q + 0.6 Temp
4) G + Q
5) G + 0.7 Q + W + 0.6 Temp
6) G + 0.7 Q + W
7) G + W + 0.6 Temp
8) G + W
9) G + 0.7 Q + 0.6 W + Temp
10) G + 0.7 Q + Temp
11) G + 0.6 W + Temp
12) G + Temp

ULS   Eurocode-1

1) 1.35 G + 1.5 Q + 0.9 W + 0.9 Temp
2) 1.35 G + 1.5 Q + 0.9 W
3) 1.35 G + 1.5 Q + 0.9 Temp
4) 1.35 G + 1.5 Q
5) G + 1.5 Q + 0.9 W + 0.9 Temp
6) G + 1.5 Q + 0.9 W
7) G + 1.5 Q + 0.9 Temp
8) G + 1.5 Q
9) 1.35 G + 1.05 Q + 1.5W + 0.9 Temp
10) 1.35 G + 1.05 Q + 1.5 W
11) 1.35 G + 1.5 W + 0.9 Temp
12) 1.35 G + 1.5 W
13) G + 1.05 Q + 1.5 W + 0.9 Temp
14) G + 1.05 Q + 1.5 W
15) G + 1.5 W + 0.9 Temp
16) G + 1.5 W
17) 1.35 G + 1.05 Q + 0.9 W + 1.5 Temp
18) 1.35 G + 1.05 Q + 1.5 Temp
19) 1.35 G + 0.9 W + 1.5 Temp
20) 1.35 G + 1.5 Temp
21) G + 1.05 Q + 0.9 W + 1.5 Temp
22) G + 1.05 Q + 1.5 Temp
23) G + 0.9 W + 1.5 Temp
24) G + 1.5 Temp

Note 

   regarding the wind case, you have always to think to consider positive and negative case, means pressure/suction loading

Case where we have : G & Q & SEI


SLS   Eurocode-1

1) G + Q

ULS   Eurocode-1

1) 1.35 G + 1.5 Q
2) G + 1.5 Q


ALS   Eurocode-1

1) G + 0.3 Q + SEI
2) G + SEI
3) G + 0.3 Q + (-SEI)
4) G + (-SEI)
5) G + 0.3 Q

The content of this page is available also in other language:


Helipad ground helicopter top view